Enum ModbusClientErrorKind

Namespace
Pamoja.Modbus
Assembly
Pamoja.Modbus.dll

Why a Modbus transaction failed.

public enum ModbusClientErrorKind : byte

Fields

BroadcastRead = 2

A read was addressed to the broadcast address, which no device answers.

Exception = 9

The device refused the request with an exception.

Frame = 5

The reply failed its CRC or is not the shape its function gives.

Mismatch = 8

A well-formed reply that does not answer the request.

Port = 3

The serial port failed.

Request = 1

The request could not be built: a quantity outside what one request carries.

Timeout = 4

No complete reply arrived within the response timeout.

WrongFunction = 7

A reply answered a function other than the one asked.

WrongUnit = 6

A reply came back from a unit other than the one asked.