pamoja for TypeScript - v0.2.0
    Preparing search index...

    Interface Ina226Reading

    One INA226 conversion: the four result registers as read, and what they mean.

    interface Ina226Reading {
        bus: number;
        busMicrovolts: number;
        busVolts: number;
        current: number;
        currentAmps: number;
        currentLsbMicroamps: number;
        currentMicroamps: number;
        mathOverflow: boolean;
        power: number;
        powerMicrowatts: number;
        powerWatts: number;
        shunt: number;
        shuntMillivolts: number;
        shuntNanovolts: number;
    }
    Index
    bus: number

    The bus-voltage register.

    busMicrovolts: number

    The bus voltage in microvolts.

    busVolts: number

    The bus voltage in volts.

    current: number

    The current register.

    currentAmps: number

    The current in amps.

    currentLsbMicroamps: number

    The current step the calibration programmed, in microamps per count.

    currentMicroamps: number

    The current in microamps; negative flows the other way through the shunt.

    mathOverflow: boolean

    Whether the part's arithmetic overflowed, leaving current and power meaningless.

    power: number

    The power register.

    powerMicrowatts: number

    The power in microwatts.

    powerWatts: number

    The power in watts.

    shunt: number

    The shunt-voltage register.

    shuntMillivolts: number

    The shunt voltage in millivolts.

    shuntNanovolts: number

    The shunt voltage in nanovolts.