pub fn max_measurement_micros(
temperature: Oversampling,
pressure: Oversampling,
humidity: Oversampling,
) -> u32Expand description
The longest one measurement cycle can take, in microseconds.
This is the datasheet’s maximum: 1.25 ms, plus 2.3 ms per temperature sample, plus 2.3 ms per pressure sample and 0.575 ms, plus 2.3 ms per humidity sample and 0.575 ms, each term only for a measurement that is not skipped. A driver waits this long after forcing a measurement before it polls the status register.
§Arguments
temperature- temperature oversampling.pressure- pressure oversampling.humidity- humidity oversampling.
§Returns
The maximum measurement time in microseconds.
§Examples
use pamoja_sensors::bme280::{max_measurement_micros, Oversampling};
// The datasheet's worked example: temperature x1, pressure x4, no humidity.
let micros = max_measurement_micros(Oversampling::X1, Oversampling::X4, Oversampling::Skipped);
assert_eq!(micros, 13_325);