pub enum Standby {
Ms0_5,
Ms62_5,
Ms125,
Ms250,
Ms500,
Ms1000,
Ms10,
Ms20,
}Expand description
The inactive period between measurements in normal mode, the t_sb[2:0] field.
The two longest BMP280 settings become the two shortest here: codes 0b110 and
0b111 mean 10 and 20 ms on a BME280.
Variants§
Ms0_5
0.5 ms.
Ms62_5
62.5 ms.
Ms125
125 ms.
Ms250
250 ms.
Ms500
500 ms.
Ms1000
1000 ms.
Ms10
10 ms.
Ms20
20 ms.